- The cooling channels located as close to the mold surface as possible, but should pay attention to the mechanical strength of the mold material.
- Diameter cooling channels must be greater than 8 mm (8 or 10) to the public and must remain degia so to avoid the flow rate of the liquid is cooled by different cooling diameter different channels.
- cooling system should be divided into multiple zones cooled cooling channels to avoid too long leads to disparities high temperature.
- pay particular attention to the cooling of the thickest part of the product.
- thermal conductivity of cast materials is also important.
- Note to the phenomenon of warping due to different shrinkage when surface different product thickness.