3.2.1 The preparation activities *) Environmental Requirements set machine a) Use outdoor - Place the generator in a dry, flat, little dust, - Avoid placing the machine in direct sunlight where sun, put in the shade. - Place the generator on a raised surface b) Use Indoor - Place ventilated area, or make a gas pipeline off, while operating should open the door . Note: When you play in and the output of the exhaust gas always obstacles 1.5m way. The safety principles in the maintenance and repair of: a) Only qualified person is examined, security maintenance and repair of the generator. b) Always wear a mask, gloves and protective clothing when maintenance and repair generators c) Do not touch the generator with wet hands or load. d) Should keep hands, hair, and clothes away from the transmitter parts such as fan motors, belts, rotor when operating the machine. e) Do not breathe the gases emitted. f) Turn off and cooled before testing Check or add fuel. g) Do not smoke while checking or additional fuel. h) Observe correct polarity (+, -) battery source, not just using a small battery. j) Use of equipment potentially suitable for lifting or generator support. *) Check before you start the engine a) Check lubrication: - Remove the oil ruler and wipe visit and reconnect it to check the oil level. Good oil is the oil level to the mark on the ruler. When pouring lubricant must pay attention to use the right type and volume of lubricant. - Turn the block under the engine oil before. Note: The type of generator Nguyenhuypower have installed control system lubrication intelligent, if the engine will not start or will stop when the machine is running. b) Check the fuel level: - Turn ignition alarm clock observation fuel, enough to fuel before treadmill. c) Check the coolant: - Coolant must be complete, if additional water shortage right, and check the fan belt tension wind not see enough tension. b) Check the fuel level: - Turn ignition clock observation of fuel, enough to fuel before treadmill. c) Check the coolant: - Coolant must be complete, if additional water shortage right, and check the fan belt tension wind not see enough tension. 3.2.2 operating sequence with control display CGC413 After conducting and completing the checks if no unusual phenomenon, proceed ignition follow these steps: Manual operation: Disconnect all loads from the generator consumption by closing Attomat. Once ready, then turn the key and then proceed with the following procedure: The transmitter is automatically heated engine mode later Automatic explosive problem. Let the engine idle stable from 30s - 1 minute, observe test panel parameters. If no abnormalities are connecting devices with transmitter power consumption by press play or play Attomat generator supplies the load. To stop the machine, interrupt transmission before, then you want to stop press Note: If the engine can not start after 3 consecutive egotistical must 1st minutes after restart. There are ongoing problems will damage the battery. Always warm the engine when no load about 30 seconds - 1 minute before closing the power switch. Launch automatic mode Led auto key to blue, the generators are manufactured Auto, when the power grid and the machine will automatically restart when the power grid back the machine will automatically shut off. Moving from startup to startup arm automatic mode transmitter will switch from boot to boot hands automatic mode active Run not load Note: You can stop the generator quickly in case of a breakdown by pressing "Emergency Stop" external enclosure. SECTION 4: INSTRUCTIONS FOR MAINTENANCE MAINTENANCE GENERATOR To increase the life of the users should pay attention to the time of operation of the machine for easy monitoring and conducting regular maintenance. 4.1 Cleaning the air filter - Keep the air filter clean, if dirty air filter will do reducing engine power. Note: Do not run it without the air filter. If the generator operating in dusty environments, it must be cleaned more frequently. 4.2 Replace lubricant Explosive Idle until warm enough, then start the process shutdown replaced by the following: Open size visited oil . Use a tray with oil under the oil drain seat, open the oil drain screws, then tighten the screws complete discharge properly tightened its regulations. Pour the oil slowly, avoid melting patchy outside the unit, check the oil under the oil level , the highest oil clinging to the mark as well. Note: To replace the oil filter periodically, or in the way memory is 02 times 01 times oil change filter change. 4.3 Changing the coolant - For regular water changes made after a period of work, if the water surface of dust must be clean. + Coolant is a mixture including water and LCC solution. + appropriate ratio of LCC and water mixture is 30 - 50 %. If the ratio falls below 305, the antifouling effect of the mixture will fall. + When additional LCC, need to use the same label and the same concentrations. 4.4. Drain fuel and water e - Push the air out of the fuel supply pipe (phenomenon e) when to restart the engine due to fuel shortage. - Remove the "fuel supply pipe out" to remove air and then rematch. - Reduction of air using fuel pump on the fuel filters. Press fuel pump to push air out of the fuel supply pipe. - Check the buffer spring of fuel filters. - Use of filters wrench to remove the cushion springs springs. - Rinse the filter and Apply a thin layer of oil on the surface of the filter and then reinstall it. Do not squeeze too. - After changing the buffer springs need to push air out of the fuel tube. TABLE SCHEDULE OF THE MAINTENANCE OF KÌ
đang được dịch, vui lòng đợi..