On 9/10/2010, discovery Ride maintenance parts on screen controls game Iron Horse error should have been down this game's room and discovered the notorious smell should have shut down the source, then informed Mr. Nguyen Dinh Phu, Phu he called the contractor Free Command to test and identify is a fire circuit of the inverter. At the time this incident occurred, Mr. Jos are vacation After the crash, the technical staff of the ASP had anticipated some causes can lead to fire short circuit board as follows: due to the humidity, insects crawl, due to dust, because the device has used more than 5 years in the us. We ordered a new circuit board PMUS instead.* Control factors of temperature and humidity in your room:Through information from company Asia Park, on 20/10/2015 BKS has recommended clarifying the following: in the documentation (manual) maintained by Vekoma transfer, the talk about the environmental conditions necessary to operate equipment, and in the need to periodically check of maintenance parts are no items requested need to check on the temperature the necessary humidity, as required or not?. Maintenance Department confirmed: in the document of the Vekoma no recommendations about the temperature and the humidity necessary to ensure your system works normally. So, in your room also does not yet have installed the thermometer and humidity measurement devices to track. After the incident occurred, on 22/10/2015 Mr Jos had email sent to Vekoma to clarify information about the conditions of temperature and humidity is suitable to operate the electrical room safely. Vekoma parties have determined response "electrical equipment can operate well in humidity from 30% to 95% (non-condensing). Electric room temperature not exceeding 35° c. However recommended as long as temperatures should hold 20° C ". The APC currently has purchased the thermometer and humidity measurement devices. * In-cell activities: On 28/10/2015 Control Board has collaborated with PMU officers checked the room and noted the following: Electrical cabinets are placed in rooms have air conditioner, electric cabinet inside had put the dryers and exhaust fans. According to the operating procedures, the source of the total will be turned when the operation and close the breaker after finishing using the games. So how to connect and operate as current, after each shift, so turn off the ngồn of the device should be drying and exhaust fans cannot guarantee 24-7. About the proposed disconnect source when the ca but still ensures continuous operation of equipment for drying and exhaust fan, he has suggested that when turned off then just turn off the CB device protection individually in electric, do not turn off the main source. BKS proposals need to connect back to the feed system for drying and exhaust fans, directly to the primary source to be sure when to turn off the CB still ensure total 2 this device works. There have been no documentation handled respectively by nature of incidents should occur when there is trouble, it switches off.* About the drainage work around your room area and moist causing source: The area around your room yet designed drainage infrastructure. During the storm of 3 ngảy 13/9/2015, rain water has flooded around the area, ascent and spill into the room through electrical wall plates has been opaque to install control wiring trunking game Iron Horse, standing water in the pit the power cable inside the room. Then pump the water out of the pit were PMUS. PMU released drawings and constructed drainage infrastructure around the area, however the present wall plate openings yet to be sealed. BKS has proposed FOUR SITES need to be designed to handle this hole.
đang được dịch, vui lòng đợi..