THU DUC DISTRICT HOSPITALHEMATOLOGY BLOODTHE PROCESS OF TROUBLESHOOTING BIOSAFETYNo: 14/QT-HHTMIssued: 12 timesDate://2016Page: The editor Who reviewed The approvalThey named Nguyen Thi Thu Thuy master Vo Van Hai BS. Nguyen Minh QuanSign your name Ngày …… / …… / …… …… / …… / …… …… / …… / ……TRACK CHANGES TO A DOCUMENTVersion, consider the location to modify the content modified/reviewed On this page change/review The modified/reviewed 1. purposeDone to solve the problems of biosafety when happened quickly, precisely, limiting the risk of exposure for medical staff and community.2. scope of APPLICATIONApply at blood transfusion Hematology-Thu Duc District Hospital.3. EXECUTION AUDIENCE-Blood transfusion Hematology personnel.4. CONCEPTS, definitions5. ABBREVIATIONS-PXN: laboratory;-MLT: centrifuges.6. REFERENCES-Decision No. 3049/QD-BYT on August 4, 2006, the Ministry of health about the establishment of the Advisory Committee for biological safety.-Decision No. 43/2007/QD-BYT on 3 December 2007 the Ministry of Health issued a regulation on waste management.- Luật Phòng, chống bệnh truyền nhiễm của Quốc hội khóa XII, Kỳ họp thứ 2, số 03/2007/QH12 ngày 21 tháng 11 năm 2007.- Nghị định số 92/2010/NĐ-CP ngày 30 tháng 8 năm 2010 Quy định chi tiết thi hành Luật Phòng, chống bệnh truyền nhiễm về đảm bảo an toàn sinh học tại phòng xét nghiệm.- Thông tư số 25/2012/TT-BYT ngày 29 thang 11 năm 2012 ban hành Quy chuẩn kỹ thuật quốc gia về thực hành và an toàn sinh học tại phòng xét nghiệm.7. NỘI DUNGNguyên tắc xử lý sự cố an toàn sinh học:- Xử lý tại chỗ;- Lưu giữ hồ sơ sự cố;- Báo cáo với người phụ trách Phòng xét nghiệm.7.1. Xử lý sự cố kim đâm vào tay khi làm việc với tác nhân gây bệnhBáo với đồng nghiệp làm việc gần đó (Nếu có);Bộc lộ vết thương (Cởi hoặc xé găng tay);Đưa ngay vết thương dưới vòi nước sạch;Để vết thương tự chảy máu trong một thời gian ngắn, không nặn bóp vết thương;Rửa khu vực vết thương kỹ bằng xà phòng và nước sạch;Sử dụng băng gạc với chất khử nhiễm thích hợp để che vết thương;Rời khỏi PXN như thường lệ;Ghi chép và báo cáo với người phụ trách PXN;Tùy từng trường hợp cụ thể có cách xử lý tiếp theo phù hợp.7.2. Troubleshooting pour, spill containing pathogensInstead of gloves, glasses;Use clamp clamp the tool model for packaging into infectious waste bags, sharp dropped into sharps containers;Absorbent paper cover up spilled fluids from the outside in;Pour the chemicals sterilizing up spilled from the outside in;For about 30 minutes for decontamination substances effective bactericide;Instead of new gloves;Wipe the absorbent paper and spilled into infectious waste bags;Recording, reporting the incident to the officers in charge of PXN.7.3. Troubleshooting the broken pipe, contain pathogens in centrifugeIf an active MLT then shutdown, still close the lid, to 30 minutes for the gas down off;If after opening the lid, pour discovered broken MLT: immediately close the cover again, go out of the room.With the same colleagues leave PXN and shut the door;Most recent warning signs for people around in the doors;Wait 30 minutes for the gas down;Wear glasses, gloves, glasses on troubleshooting;Use absorbent paper with high proper decontamination wipe inside of MLT;Using tongs remove debris for test tubes into containers for sharp instruments;Decontamination for rotor centrifugal machine and Cup with the appropriate solution;Recording, reporting the incident to the officers in charge of PXN.7.4. Troubleshooting fireAvoid making people injured;Alerts with colleagues to evacuate;Activate the fire alarm bell;Close the door;Evacuate to a safe place.8. FORMS/RECORDS The shared recorded incidents
đang được dịch, vui lòng đợi..
